Add to Cart
Seamless Tube Coil Boiler Spare Parts Superheater and Reheater for Waste Heat Boiler
Description
Summary
For power plant boiler, it is a crutial way to increase thermal economy of thermal power station by improving parameter of superheated steam. The increase of superheated steam parameters are limited by metal materials. The design of superheaters must make sure that the temperature of outer wall of heating surface pipes is lower than allowable temperature of oxidation resistance of steel, and meanwhile make sure its mechanical strength. with the development of metal material used in boilers, pwoer station boilers in our country already generally apply high pressure, high temperature(9.8MPa, 540 degrees) and superhigh pressure parameters(13.7 MPa, 540 and 555 degrees), and have developed subcritical pressure parameters(16.7MPa, 540 and 555 degrees). Now lots of boilers apply supercritical pressure parameters(24.5MPa, 540-570 degrees), and even very few units apply higher pressure and temperture parameters.
Details
• Superheating raises overall efficiency as well as avoids too much condensation in last stages of turbine which avoids blade erosion.
• The heat of combustion gases from furnace is utilised for removal of moisture from steam and to superheat the steam.
• Super-heaters ususlly have several tube circuits in parallel with one or more return bends,connected between headers.
• Heat from the hot gases to the vapour in the surperheater is transferred at high temperatures.
• Therefore promary section of superheater is arranged in counterflow and secondary section in parallel flow to reduce the temp.stressing of the tube wall.
Application
use for heating saturated steam, steam temperature could be up to 900 degree C.
Superheater Capacity Upgrades to Increase Power Generation
Send us required technical data, such as steam capacity, presure, required temperature etc. We will design accordingly.
Differences
Type | Advantages | Disadvantages | Supporting method |
Pendant-type | 1.Firm structural support | 1. Flow blockage by condensed steam 2. Needs slow restart to purge the water that accumulates in the bottom. | supported from above |
Inverted-type | 1.Proper drainage of the condensed steam | 1. Lack the structural rigidity, especially in high speed gas flow | Supported from below |
Horizontal -type | 1. Proper drainage 2. Good structural rigidity. | 1. They do not view the flam directly so they are mainly from the convective type | Usually supported in the vertical gas ducts parallel to the main furnace. |