Zhangjiagang HuaDong Boiler Co., Ltd.

Zhangjiagang HuaDong Boiler Co., Ltd.

Manufacturer from China
Verified Supplier
9 Years
Home / Products / Boiler Manifold Headers /

Carbon / Stainless Steel Boiler Manifold Headers For Power Plant HD Boiler

Contact Now
Zhangjiagang HuaDong Boiler Co., Ltd.
Visit Website
Province/State:jiangsu
Country/Region:china
Contact Person:MissSandy Chen
Contact Now

Carbon / Stainless Steel Boiler Manifold Headers For Power Plant HD Boiler

Ask Latest Price
Video Channel
Brand Name :HDB
Model Number :Boiler Manifold Header
Certification :ISO9001 , SGS , TUV , ASME , EN
Place of Origin :Jiangsu , China
MOQ :1 Set
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :800tons/month
Delivery Time :30 working days
Packaging Details :Wooden Case
Condition :New
Dimension :Depends
Type :Ultra Super Critical
Material :15CrMoG / 12Cr1MoVG
OEM :Yes
Color :Red / Blue / White
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
Carbon Steel Boiler Manifold Headers For Power Plant HD Boiler

Product Description

Steam distribution headers are fabricated out of carbon steel or alloy steel seamless tubes. Customized or tailor made items are offered. Headers, after fabrication, are stress relieved to make the Steam distribution headers free from stresses. They are big pipe headers that transfer water from the downcomers to the risers through a combustion zone where the water gets partially heated to steam from the heat of fuel combustion.

Operation

In bringing a boiler on the line with other boilers on a header system,certain precautionss are necessary to avoid water hammer and excessive temperature gradients in the piping. Adequate drainage and warming of the piping will eliminate the risk of water hammer. The judicious use of bypass valves around main header valves will avoid steep temperature gradients. Header drains should be operated. The steam line from the boiler to the header should be brought up to temperature by operating bypass and drain valves. When up to temperature and line pressure, the header valve may be opened wide and the bypass closed.

Technical parameters

Diameter(OD) ¢76mm~¢914mm
Length(Max) 23000mm
Temperature(℃) 300~1500
1 Headers form an important part of all types of boilers.
2 Steam from the generating tubes is collected in headers which are therefore always under pressure.
3 This pressure may vary from 300 psi to 2000 psi. Since headers are always under pressure, the utmost care is taken by us while fabricating them.
4 Depending on the generating capacity of the boiler the header sizes fabricated by us vary from 100 mm to 600 mm NB. The stubs of various sizes are very carefully welded to the main body of the header to provide the desired openings from the header.

Carbon / Stainless Steel Boiler Manifold Headers For Power Plant HD Boiler

Material

1. Carbon steel:20G,SA-106B,SA-106C,etc.

2. Low-alloy thermal resistant steel:15CrMoG,12Cr1MoVG,SA-335P12,SA335-P22,etc.

3. Middle-alloy thermal resistant steel:SA-335P91,etc.

4. Special material(ultra-supercritical):SA-335P122,SA-335P92,etc.

The boiler headers have water wall header,superheater header,economizer header and so on. It acts action of gathering, mixing and redistribution in boiler systems. In structure, they include end cover hinders or necking hinders.

Features

1. Strength calculation report with applied materials information.
2. 100%NDT(non-destructive inspection) report of steel plate, tube and welding rod.
3. 100%X-ray inspection report (welding seam): to ensure the quality of the entire boiler.
4. Hydraulic test report: ensure the standard working pressure and safety.

5.Excellent in welding quality, highly automatic, safe and reliable.

Carbon / Stainless Steel Boiler Manifold Headers For Power Plant HD Boiler

Classification

In bringing a boiler on the line with other boilers on a header system,certain precautionss are necessary to avoid water hammer and excessive temperature gradients in the piping. Adequate drainage and warming of the piping will eliminate the risk of water hammer. The judicious use of bypass valves around main header valves will avoid steep temperature gradients. Header drains should be operated. The steam line from the boiler to the header should be brought up to temperature by operating bypass and drain valves. When up to temperature and line pressure, the header valve may be opened wide and the bypass closed.
Parameters

Diameter(OD)

¢76mm~¢914mm

Diameter(OD)

23000mm

Temperature(℃)

300~1500

Application

Steam distribution headers are fabricated out of carbon steel or alloy steel seamless tubes. Customized or tailor made items are offered. Headers, after fabrication, are stress relieved to make the Steam distribution headers free from stresses. They are big pipe headers that transfer water from the downcomers to the risers through a combustion zone where the water gets partially heated to steam from the heat of fuel combustion.

Factory Workshop

Product Tags:
Inquiry Cart 0