Add to Cart
Energy Saving Electric Steam Hot Water Boilers For Industry & Power Station
Product Infomation
Advantages
Parameter
Model | SZL6- 1.25-AII 1.6-AII 2.5-AII | SZL8- 1.25-AII 1.6-AII 2.5-AII | SZL10- 1.25-AII 1.6-AII 2.5-AII | SZL15- 1.25-AII 1.6-AII 2.5-AII | SZL20- 1.25-AII 1.6-AII 2.5-AII | SZL25- 1.25-AII 1.6-AII 2.5-AII | SZL30- 1.25-AII 1.6-AII 2.5-AII | |
Rated heating efficiency(MW) | 6 | 8 | 10 | 15 | 20 | 25 | 30 | |
Rated working pressure(MPa) | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | |
Rated steam temperature | 193/2 04/226 | 193/2 04/226 | 193/2 04/226 | 193/2 04/226 | 193/ 204/226 | 193/204/226 | 193/204/226 | |
Rated outlet temperature | 60 | 60 | 60 | 60 | 104 | 104 | 104 | |
Heating area | Boiler(m2) | 156 | 197.4 | 235.6 | 412 | 508 | 510 | 588.6 |
Coal econo mizer(m2) | 87.2 | 157 | 174.4 | 413/413/236 | 357 | 496 | 450 | |
Air pre heater (m2) | -/-/181 | 199 | 212 | 210 | ||||
Effective area of grate(m2) | 7.8 | 10.1 | 11.8 | 17.3 | 21 | 24.3 | 25.8 | |
Water volume(m3) | 7.3 | 9.6 | 12.4 | 15.3 | 21.6 | 27 | 27.6 | |
Design efficiency(%) | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |
Applicable fuel | Soft Class II | |||||||
Maximum size of shipping part(m) | 6.1× 3.1×3.5 | 6.8× 3.4×3.5 | 7.6× 3.4×3.5 | 9.6× 3.4×3.54 | 11× 3.41×3.54 | 8.3× 3.0×3.6 | 8.5×3.6×3.64 | |
Maximum weight of shipping part(t) | 25 | 29 | 31 | 42 | 50 | 22/28 | 23/29 | |
Overall size of installation(m) | 9.5× 5.5×6.2 | 9.5× 5.5×6.2 | 9.8× 5.7×6.2 | 10.9 ×5.7×6.7 | 12× 5.8×6.8 | 13.8× 6.0×10.6 | 18×6×10.5 | |
Draught fan | GY6-1 30kw | GY10-1 45kw | GY10-15 55kw | Y5-47 12D 75kw | GY5-47 12.4D 90kw | GY20-15 110kw | GY35-15 132kw | |
Blower fan | T4-72 5A 11kw | GG10-1 15kw | GG10-1 15kw | G4-73 9D 30kw | G4-73 9D 30kw | GG20-15 55kw | G40-73 10D 55kw | |
Speed governor | GL-10P 0.75kw | GL-16P 1.1kw | GL-16P 1.1kw | GL-20P/II 1.5kw | GL-20P/II 1.5kw | GL-30P 2.2kw | GL-40P 3kw |
Company Introduction
Design and development
Collect all parameters for product design, make design acording to the Supervisory Regulations on Boiler Safety Technology, other laws, rules, regulations and professional standards, and 100% meet the product standards and customers' requirements.
Supervision and confirmation
The quality and technical supervision administration authorizes the inspection agency stationed on site to supervise, inspect and test the process of boiler manufacturing.Accept supervision or confirmation of the third party or Customer's representative over the process of boiler manufacturing.